The capacity printed on a bilge pump is usually measured at open flow, with no lift, and often at 13.6 volts. Installed, it can move a lot less. Sizing one well means deciding what job each pump has, working out what it will really move, and plumbing and wiring it to get close to its rating.
1. Decide what each pump is for
A common setup is two electric pumps plus a high-water alarm:
- Primary pump: a smaller automatic pump at the lowest point of the bilge that handles rainwater and small leaks. The Rule-Mate 500 and Rule-Mate 1100 sense water themselves, so they don't need a separate float switch.
- High-capacity backup: a larger pump mounted a few inches higher, so it runs only when water rises past the primary. Examples include the Rule 2000 Automatic (53S) and the Johnson Pump 2200 GPH Ultima Combo, which comes prewired with a float switch that has a manual override.
- High-water alarm: warns you when water outpaces the primary. The Rule Hi-Water Bilge Alarm pairs a float switch with a dash gauge that gives a visual and audible warning.
2. Read the rating the right way
Check the voltage behind each rating. Rule's spec sheets for larger pumps such as the 2000 and 3700 give capacity at 13.6 volts and list lower figures at 12 volts, while Rule rates its newer small pumps, including the Rule-Mate and electronic sensing models, at 12 volts. Johnson Pump quotes its heavy-duty pump capacities at 13.6 volts. Compare pumps on the same basis.
3. Estimate what it will really pump
Lift is how high the pump has to push water, from the pump to the highest point in the discharge line, such as a vented loop. More lift and lower voltage both cut output. Rule's own figures show how much:
- The Rule 3700 (14A) is rated at 3,700 GPH at open flow and 13.6 volts. At 12 volts with 6.7' of lift, Rule lists 2,100 GPH.
- The Rule 2000 (53S) drops from 2,000 GPH to 1,160 GPH under the same conditions.
Measure your lift, look up the maker's output at that height and at 12 volts, and size from that figure. Hose length, bends and fittings cut flow further, so leave margin.
4. Match the hose and plumbing
- Use the pump's hose size. Rule notes that a smaller hose reduces output and a larger one won't increase it. Sizes vary by pump: 3/4" for the Rule-Mate 500, 1-1/8" for the Rule 2000 and 1-1/2" for the Rule 3700.
- Run it steadily upward. Pumps like the Rule 2000 and 3700 aren't self-priming, and both Rule and Johnson Pump call for a discharge hose that rises continuously from the pump without dips. Johnson Pump recommends smooth-bore, reinforced hose for the best flow.
- Place the outlet high. Johnson Pump recommends a discharge point at least 1' above the waterline by the shortest route, and Rule recommends a vented loop to prevent siphoning. See our guide to thru-hull fittings and seacocks.
- Avoid check valves unless you need one. They reduce flow. Rule's installation manual says to use one only to stop an automatic pump from cycling as water drains back from the hose, and never in a discharge line shared by several pumps.
5. Wire and switch it correctly
- ABYC standards call for each bilge pump circuit to have its own overcurrent protection. Use the fuse size the maker specifies: Rule lists 15 amps for the Rule 2000 (53S) and 25 amps for the 3700 (14A).
- Voltage drop lowers output, so size wire for the pump's current and run length; Rule advises heavier wire for longer runs. Ancor bilge pump cable is tinned, three-conductor wire made for bilge pumps. See marine wiring basics.
- For pumps without built-in sensing, the Rule ECO-Switch uses air pressure in a tube to turn the pump on, keeping its wiring out of the water.
- A helm panel such as the Blue Sea 8664 Contura 2 gives two pumps ON-OFF-AUTO switches with fuse holders and a running light.
6. Keep a manual pump aboard
A manual pump such as the Jabsco Amazon Universal keeps working when the battery doesn't. If a cartridge-style pump quits, see how to replace a bilge pump motor cartridge.
Quick checklist
- Plan a small automatic primary, a larger backup mounted higher and a high-water alarm.
- Check the voltage and lift behind each pump's rating.
- Size from the maker's output at your lift height and 12 volts, with margin.
- Use the pump's hose size, run it steadily upward and skip check valves unless needed.
- Fuse each pump to the maker's spec and size the wire for the run.
- Carry a manual pump.